Tool

Reciprocity calculator

Long exposures need more time than the meter says. This uses each film's own datasheet: a formula when the manufacturer gives one, its table otherwise. Nothing is extrapolated past the published times.

Calculate

Metered 30 s

+1.33 stops

  • Open the aperture; the datasheet gives no corrected time for this.

Straight from the datasheet table.

ADOX HR-50: datasheet values

MeteredOpen upOr expose
1/2 s+0.33 stops—
1 s+0.33 stops—
2 s+0.67 stops—
4 s+0.67 stops—
8 s+0.67 stops—
15 s+1 stop—
30 s+1.33 stops—

Source: ADOX Fotowerke ADOX HR-50 technical description (2018-11)

Everything else about this film: ADOX HR-50.

Same data from the API