Development times

Ilford Pan 400 in Ilford Ilfotec DD

4 times for 1+4, EI 200–1600, 24 °C. From HARMAN technology ILFORD PAN 100 / PAN 400 fact sheet (2002-03).

Times

1+4 · intermittent

Ilford Pan 400 in Ilford Ilfotec DD 1+4 · intermittent: time in minutes:seconds by exposure index and temperature
EI24 °C
2005:00
4006:00
8008:00
160011:00

Source: HARMAN technology ILFORD PAN 100 / PAN 400 fact sheet (2002-03)

Time in min:sec. A dash means the source gives no time for that combination; rolllog doesn't fill gaps. These are starting points: test with your own process.