Development times

Ilford HP5 Plus in Ilford ID-11

6 times for 1+1, 1+3, stock, EI 400–1600, 20 °C. From HARMAN technology HP5 PLUS Technical Information (2018-11).

Box speed (EI 400), 20 °C, 1+1, intermittent
13:00
Box speed (EI 400), 20 °C, 1+3, intermittent
20:00
Box speed (EI 400), 20 °C, stock, intermittent
7:30

Times

1+1 · intermittent

Ilford HP5 Plus in Ilford ID-11 1+1 · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
40013:00
80016:30

1+3 · intermittent

Ilford HP5 Plus in Ilford ID-11 1+3 · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
40020:00

Stock · intermittent

Ilford HP5 Plus in Ilford ID-11 Stock · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
4007:30
80010:30
160014:00

Source: HARMAN technology HP5 PLUS Technical Information (2018-11)

Time in min:sec. A dash means the source gives no time for that combination; rolllog doesn't fill gaps. These are starting points: test with your own process.