Development times

Rollei RPX 400 in Ilford ID-11

5 times for 1+1, 1+3, stock, EI 400–800, 20 °C. From Rollei RPX 400 Data Sheet (2025-11).

Box speed (EI 400), 20 °C, 1+1, intermittent
14:00
Box speed (EI 400), 20 °C, 1+3, intermittent
25:30
Box speed (EI 400), 20 °C, stock, intermittent
8:00

Times

1+1 · intermittent

Rollei RPX 400 in Ilford ID-11 1+1 · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
40014:00
80018:00

1+3 · intermittent

Rollei RPX 400 in Ilford ID-11 1+3 · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
40025:30

Stock · intermittent

Rollei RPX 400 in Ilford ID-11 Stock · intermittent: time in minutes:seconds by exposure index and temperature
EI20 °C
4008:00
80011:00

Source: Rollei RPX 400 Data Sheet (2025-11)

Time in min:sec. A dash means the source gives no time for that combination; rolllog doesn't fill gaps. These are starting points: test with your own process.

Rollei RPX 400 in other developers

Other films in Ilford ID-11

Same data from the API

curl "https://rolllog.io/api/v1/films/rollei-rpx-400/dev-times?developer=ilford-id-11"

All of Rollei RPX 400: exposure, reciprocity, formats and prices.